Introduction
Condition Based Maintenance made easy with the new X-Viber and the X-Trend software system
This instrument is designed for Condition
Monitoring and Predictive Maintenance
work without the need for "expert"
interpretation.
Not only can it be used in a condition
based maintenance program it is also an
ideal instrument for supporting a
Preventive Maintenance (PM) program.
By setting a base line measurement you
can compare the PM results to the base
line before and after any work. This is also
an excellent practice when commissioning
equipment back into service.
To control any process you need to
measure. With the X-Viber you choose
the parameter you want to measure
Vibration/Temperature/Bearing
condition etc. and the X-Trend expert
software automatically trends the
measurements.

This simple to use X-Viber instrument offers two main functions: Route and Measurement. Please click on the appropriate page for more details. Also visit our Downloads page where you can download a PDF of this site as well as a copy of the software. You can also download a PDF instruction overview and an x-viber demo.
Please review the Technical and Preliminary data and also note that the Route transfer to Computer Software is via USB connection.
Call or e-mail info@x-viber.com if you have any questions on this X-Viber. Let us know your location etc. and we can send you a quotation.
X-Viber is distributed by Benchmark Maintenance Services Inc. and their agents.
Tel. 1-800-598-1117 or (905) 509-6522
Web: www.withinspec.com
Email: info@withinspec.com
Technical data | Preliminary |
Standard vibration transducer |
|
| Accelerometer type | AC140-2A |
| Sensitivity | 100mv/g |
| Frequency range | (+/-3db 1-10000Hz |
| Resonance frequency | 23000Hz |
| Temperature range | -50 °C ... +121°C |
| Mounting | Magnet holder, hand held or measurement point |
| Cable length | 1m |
Vibration input electrical specification |
|
| Maximum insignal level | +/-5V Peak |
| Transducer signal Accelerometer | 100mv/g |
| Current- and power supply to transducer | +4mA constant current at maximum 20V for accelerometer |
| Built in speed transducer | Infrared photocell |
| Measurement range | 30 - 120.000 rpm |
| Measurement distance | 0.15 - 1m |
| Measurement object | Reflective tape on the shaft |
| Automatic comparison with selectable alarm levels | Yes, 2 different limit values |
Built in temperature transducer |
|
| Measurement range | -33 to +220°C |
| Accuracy | ±1°C |
| Resolution | 0.5°C |
| Measurement distance | 0.05 to 1m |
| Automatic comparison with selectable alarm levels | Yes, 2 different limit values |
Measurement properties |
|
Total level vibration |
|
| Selectable frequency ranges | 1-800Hz, 2-1600Hz, 4-3200Hz, 8-6400Hz |
| Selectable measurement units, Metric | mm/s, um, mm, m/s, g |
| Selectable measurement units, Imperial | in/s, mils, thou, g |
| Selectable type of average | RMS, Peak, P-P |
| Automatic comparison with selectable alarm levels | Yes, 2 different limit values |
Total level Envelope |
|
| Frequency range for transducer signal | 800 - 6000Hz |
| Envelope level within the frequency range | 1 - 1000Hz Unit gE RMS |
| Automatic comparison with selectable alarm level | Yes, 2 different limit values |
Total level bearing condition |
|
| Frequency range at bearing condition measurement | Selectable between 0.5 - 8kHz, 1 -8kHz, 2 - 8kHz, 4 -8kHz Unit g RMS |
| Automatic comparison with selectable alarm levels | Yes, 2 different limit values |
| Analysis | Same properties as with total level vibration Automatic analysis of 5 frequencies with the highest levels |
| Route | Downloaded from PC-software |
| Memory capacity | App. 999 measurement points |
Other |
|
| Dynamic measurement range | 80dB |
| Autoscale | Yes |
| Mainprocessor | Microprocessor 38Mhz |
| Internal memory | 512kb Flash, 512kb RAM |
| Graphic display | 68x124 pixel with background light |
| Realtime clock | Yes |
| Computer communication | USB maximum 115kb |
| Power supply | 4 x R6 1800mA rechargeable NiMh batteries |
| Power usage at measurement / waiting mode | 400mA / 200mA./ 4uA Å6 hour operation |
| Min/max surround temperature at measurement | -20 °C ... +50°C |
| Dimensions | 180 x 80 x 40mm |
| Weight | 400gram inclusive batteries |