X-Viber
Condition-based Maintenance
This instrument is designed for Condition Monitoring and Predictive Maintenance work without the need for "expert" interpretation. Not only can it be used in a condition based maintenance program it is also an ideal instrument for supporting a Preventive Maintenance (PM) program. By setting a base line measurement you can compare the PM results to the base line before and after any work. This is also an excellent practice when commissioning equipment back into service so you can control any process you need to measure. With the X-Viber you choose the parameter you want to measure i.e. Vibration/Temperature/Bearing condition, etc. and the X-Trend expert software automatically trends the measurements.
Features:
- 1 handheld display
- 1 transducer with magnet
- 1 USB connection cable
- 1 Battery charger
- 1 Extension probe
- 1 X-Trend software for trending and basic analysis
- 1 Carrying case
- 1 Manual
X-Viber Measurements
Among its single plane balancing feature, the X-Viber has two main functions: Route and Off-Route Measurements. When using the Route function you can record, store and trend the measurement data in the X-Trend software that comes with the instrument. The Off-Route Measurement function can only record the data on the display. Both functions come with the following measurements:
Total Value - This value is the RMS average of all vibrations within the selected frequency range. You can select both unit and frequency range.
Bearing Condition - This value is the RMS average in "g" of all high frequencies within the selected frequency range.
Envelope - This value is the RMS average in "gE" within the selected frequency range 2-1000 Hz of the low pass filtered and rectified high frequencies between 500 to 7200 Hz. You can select between different frequency ranges.
Speed - X-Viber is remotely measuring the shaft speed between 30 to 12000 rpm by sensing infrared reflex from a target on the shaft. The target can be any reflex tape.
Temperature - This function is used to measure the temperature of the machine or bearing.
Analysis - This function is similar to the Total Value but with an additional analysis of the 5 dominating frequencies in the signal. This function is especially useful to find the cause of vibration and at balancing. You can also select both unit and frequency range.
X-Viber Specifications
Standard vibration transducer - Accelerometer type AC199-28
| Sensitivity | 100 mv/g |
| Frequency range (+/-3 dB) | 1-1000 Hz |
| Resonance frequency | 23000 Hz |
| Temperature range | -50°C … +121°C |
| Mounting | Magnet holder, hand held or measurement point |
| Cable length | 1 m |
Vibration input electrical specification
| Maximum insignal level | +/- 5V Peak |
| Transducer signal | Accelerometer 100mV/g |
| Current and power supply | +4mA constant current at maximum |
Built in speed transducer (Infrared photocell)
| Measurement range | 30 - 120.000 rpm |
| Measurement distance | 0.15 - 1 m |
| Measurement object | Reflective tape on the shaft |
| Automatic comparison with selectable alarm levels | Yes, 2 different limit values |
Built in temperature transducer
| Measurement range | -33 to +220°C |
| Accuracy | ±1°C |
| Resolution | 0.5°C |
| Measurement distance | 0.05 to 1 m |
| Automatic comparison with selectable alarm levels | Yes, 2 different limit values |
Total level vibration
| Selectable frequency ranges | 1-800Hz, 2-1600Hz, 4-3200Hz, 8-6400Hz |
| Selectable measurement units, Metric | mm/s, um, mm, m/s, g |
| Selectable measurement units, Imperial | in/s, mils, thou, g |
| Selectable type of average | RMS, Peak, P-P |
| Automatic comparision with selectable alarm levels | Yes, 2 different limit values |
Total level Envelope
| Frequency range for transducer signal | 800 - 6000Hz |
| Envelope level within frequency range | 1- 1000Hz |
| Unit | gE RMS |
| Automatic comparison with selectable alarm level | Yes, 2 different limit values |
Total level bearing condition
| Frequency range at bearing condition measurement | selectable between 0.5 – 8kHz, 1 -8kHz, 2 – 8kHz, 4 -8kHz |
| Unit | g RMS |
| Automatic comparision with selectable alarm levels | Yes, 2 different limit values |
Analysis
| Same properties as with Total Level Vibration | Automatic analysis of 5 frequencies with highest levels |
Route
| Memory | App. 999 measurement points |
Other
| Dynamic measurement range | >80dB |
| Autoscale | Yes |
| Main processor | Microprocessor 38 Mhz |
| Internal memory | 512kb Flash, 512kb RAM |
| Graphic display | 68x124 pixel with background light |
| Realtime clock | Yes |
| Computer communication | USB maximum 115kb |
| Power supply | 4 x R6 1800mA rechargeable NiMh batteries |
| Power usage at measurement / waiting mode | 400mA / 200mA./ 4uA ≈6 hour operation |
| Min/max surround temperature at measurement | -20°C … +50°C |
| Dimensions | 180 x 80 x 40 mm |
| Weight | 400 g including batteries |
X-Viber Software
The following is a brief overview of the software and how it is used. For more information, please contact info@benchmarkpdm.com.