Viber X3™
Basic Condition-based Maintenance
The Viber X3™ is designed for use after general maintenance or repair work, giving tradesman the ability to verify the results of their work. The instrument takes overall vibration reading, bearing condition (including the use of headphones) and temperature. It is an excellent tool for basic condition monitoring measurements, and it is very simple to use at an unbeatable price!
Click the VIDEO tab --> to watch a demonstration on the VIBER X3™!
Features:
- 1 Digital display
- 1 Accelerometer
- 1 Charger
- Rechargable batteries (STD AA)
- 1 headphones
- 1 Extension tip for accelerometer
- 1 Magnetic holder for transducer
- Carrying case
Viber X3™ Measurements
Overall Vibration - This measurement takes the overall vibration of the machine.
Bearing Condition (with headphones) - This value is the RMS average in "g" of all high frequencies within the selected frequency range. Try listening (with headphones) to the bearing while greasing it. The sound will tell you when the grease hits the bearing and the ‘g’ readings will confirm the results.
Temperature - This function is used to measure the temperature of the machine or bearing.
Analysis - This function is similar to the Total Value but with an additional analysis of the 5 dominating frequencies in the signal. This function is especially useful to find the cause of vibration and at balancing. You can also select both unit and frequency range.
Viber X3™ Specifications
Input amplitude range
| Vibration | 50 g RMS |
| Bearing Condition | 50 g BC |
Frequency range
| Vibration | 2-1600 Hz (Note 1), 4-3200 Hz (Note 2), 10-1000 Hz |
| Bearing condition | Typically 1.5 to 20 KHz [Ext. 0.5 to 30 kHz (-3db)] (Note 2) |
Vibration
| Vibration units | g, mm/s, μm, in/s, mils (Note 3) |
| Vibration, presentation of amplitude | RMS, Peak, Peak-Peak (Note 3) |
Highest amplitude in frequency spectrum
| 2-1600 Hz, 4-3200 Hz, 10-1000 Hz, 4 Hz-1 KHz, 8 Hz-1 KHz, 10 Hz-1 KHz (Note 4) |
Sound Frequency
| Filter Not Connected | 10 Hz-10 KHz, + 26 dB to -66.5 dB |
| Filter Connected | 500 Hz-10 KHz, + 26 dB to -66.5 |
Accuracy
| Vibration | ± 3% (Note 5) |
| Bearing condition | ± 2 % (Note 5a) |
| Frequency | ± 0.5 Hz |
| Temperature | ± 1 °C (Note 5b) |
Vibration transducer
| Accelerometer | Standard 100 mV/g± 5% |
Battery
| Rechargeable NiMh | 3 X 1.2V cells @ 2700 mAh |
| Battery lifetime | Min.24 hours for a full charged battery pack. |
| External charger | 7.5 V regulated @ 1000 mA |
Power consumption
| Running | 100 mA (average) (Note 7) |
| Sleep mode | Less than 20μA |
Temperature
| Temperature range | -20 to 140°C |
| Temperature sensor | Built-in infrared sensor (Note 5c) |
| Operating temp. range | 0 to 80 °C (Note 8) |
Miscellaneous
| Enclosure protection | IP 65 |
| Weight | 480 g (Note 9) |
| Dynamic headphones | 32 Ohm |
| Frequency range | 20-20000 Hz |
| Volume Control | Embedded |
Notes
| Note 1 | User selectable, for non-integrating measurement units |
| Note 2 | Hardware high pass filter with -3dB attenuation at 475Hz. |
| Note 3 | User selectable |
| Note 4 | User selectable unit between Hz and CPM. |
| Note 5 | Full scale is 50g for acceleration, 200 mm/s for velocity and 3000μm for displacement. |
| Less than -3dB attenuation for lower frequencies. | |
| Note 5a | Over 0.03 gBC |
| Note 5b | Emissivity factor must be set in accordance with the target surface. |
| Note 5c | Distance to target between 100mm and 200mm. |
| Note 6 | Battery life depends on backlight and volume level in the headphone. Backlight adds about 40mA and the maximum sound volume up to 150mA. |
| Note 7 | Backlight and sound off. The power consumption is directly related with the active measurement. Temperature measurement consumes more power than vibration measurement. |
| Note 8 | Storage temperature from -20°C to 90°C. |
| Note 9 | Instrument including battery and transducer. |